Osburn Stratford Wood Fireplace Epa
Osburn Stratford Wood Fireplace Epa Osburn Stratford Wood Fireplace Epa Osburn Stratford Wood Fireplace Epa

Osburn Stratford Wood Fireplace Epa

$ 2 199.00
+
-
ADD TO CART

OB04002

STRATFORD WOOD FIREPLACE

Heres what youve been hoping to find, a decorative and efficient wood fireplace that meets EPA emissions standards.

Thats saying a lot, but the Osburn Stratford has much more to offer, including a 2.5 cubic foot firebox thats easy to access through double-cast iron doors.

The Osburn Stratford will impress you with its distinctive style and exceptional heating capacity.

Several options are available, including a forced air system for heating adjacent rooms.

Required accessories

BLACK CAST IRON DOOR OVERLAY

OA10600

BRUSHED NICKEL CAST IRON DOOR OVERLAY

OA10602

PRAIRIE STYLE FACEPLATE

OA10331\

TRADITIONAL FACEPLATE WITH BRUSHED NICKEL ACCENTS

OA10332

TRADITIONAL STYLE FACEPLATE

OA10330

Options

3'' FRESH AIR INTAKE REGISTER WITH AIRTIGHT DAMPER

AC01345

3' X 10' INSULATED FLEX PIPE FOR FRESH AIR INTAKE KIT

AC02092

4'' FRESH AIR INTAKE REGISTER WITH AIRTIGHT DAMPER

AC01347

6' X 25' INSULATED FLEX PIPE FOR FORCED AIR DISTRIBUTION KIT

AC01350

FORCED AIR DISTRIBUTION KIT 300 CFM

AC01340

HOT AIR GRAVITY DISTRIBUTION KIT MODERN WITH ADJUSTABLE PIPES

AC01389

HOT AIR GRAVITY DISTRIBUTION KIT - TRADITIONAL

AC01375

RIGID FIRESCREEN

AC01560

Appliance performance (1)

Fuel type : Dry cordwood Recommended heating area (sq.ft.) : () 750 - 2,100 Firebox volume (cu. ft.) : 2.5 Maximum burn time : () 9 h Maximum heat output (dry cordwood) : (2) 75,000 BTU/h Overall heat output rate (min. to max.) : (2) (3) 11,500 BTU/h (3.4 kW) to 30,500 BTU/h (8.9 kW) Average overall efficiency (EPA cribs / Douglas fir) : (3) 55.0 % (HHV) (4) 60.0 % (LHV) (5) Average overall efficiency (dry cordwood) : (3) N.A. (HHV) (4) N.A. (LHV) (5) Optimum efficiency : (6) (7) 75 % Average particulate emissions rate : (8) 4.4 g/h Average CO : (9) N.A.

(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft and 20 lb/ft. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft and 12 lb/ft. The moisture content is between 19% and 25%.

(3) As measured per CSA B415.1-10 stack loss method.

(4) Higher Heating Value of the fuel.

(5) Lower Heating Value of the fuel.

(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft and with a moisture content between 19% and 25%.

(7) Optimum overall efficiency at a specific burn rate (LHV).

(8) This appliance is officially tested and certified by an independent agency.

(9) Carbon monoxyde.

General features Burn rate N.A. Maximum log length 21' Log positioning Over width Recommended chimney diameter 6' Minimum chimney height (feet) 15 Baffle type High heat-resistant C-cast Approved for a mobile home installation No Weight 424 lb (192 kg) Door type Double, glass with cast iron frame Glass type Ceramic glass Glass surface dimensions (Width X Height) 22 1/4' x 12 3/8' Overall dimension (Height) 47 1/8'' Overall dimension (Width) 37 7/8'' Overall dimension (Depth) 29 5/8'' Door opening dimension (Height) 10 7/8' Door opening - dimension (Width) 25 1/2' Firebox dimension (Height) 12' Firebox dimension (Width) 20 7/8' Firebox dimension (Depth) 12 7/8'' Centre line of flue outlet to the side 18 7/8'' Centre line of flue outlet to the back 10 1/8'' USA standard (emissions) EPA Method 28 Canadian standard (emissions) CSA B415.1-10 USA standard (safety) UL 127 Canadian standard (safety) ULC-S610 Tested and listed as per applicable standards By an accredited laboratory (CAN/USA) Warranty Limited lifetime Minimum clearances to combustibles *

(Data expressed in inches. 1 inch = 25.4 mm) Canada USA Single wall pipe Double wall pipe Single wall pipe Double wall pipe Back Sides Corners Top ** 80' 80'

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Measured from the platform on which the product is installed. Some appliances have been tested with a low ceiling. If necessary, consult the owner's manual for information on these clearances to combustible materials.

Fuel type : Dry cordwood Heating area : 750 - 2,100 Ft2 Maximum heat output : 75,000 BTU/h